17 research outputs found

    Department of Homeland Security Science and Technology Directorate: Developing Technology to Protect America

    Get PDF
    In response to a congressional mandate and in consultation with Department of Homeland Security's (DHS) Science and Technology Directorate (S&T), the National Academy conducted a review of S&T's effectiveness and efficiency in addressing homeland security needs. This review included a particular focus that identified any unnecessary duplication of effort, and opportunity costs arising from an emphasis on homeland security-related research. Under the direction of the National Academy Panel, the study team reviewed a wide variety of documents related to S&T and homeland security-related research in general. The team also conducted interviews with more than 200 individuals, including S&T officials and staff, officials from other DHS component agencies, other federal agencies engaged in homeland security-related research, and experts from outside government in science policy, homeland security-related research and other scientific fields.Key FindingsThe results of this effort indicated that S&T faces a significant challenge in marshaling the resources of multiple federal agencies to work together to develop a homeland security-related strategic plan for all agencies. Yet the importance of this role should not be underestimated. The very process of working across agencies to develop and align the federal homeland security research enterprise around a forward-focused plan is critical to ensuring that future efforts support a common vision and goals, and that the metrics by which to measure national progress, and make changes as needed, are in place

    Study protocol for an evaluation of the effectiveness of ‘care bundles’ as a means of improving hospital care and reducing hospital readmission for patients with chronic obstructive pulmonary disease (COPD)

    Get PDF
    BACKGROUND: Chronic Obstructive Pulmonary Disease is one of the commonest respiratory diseases in the United Kingdom, accounting for 10 % of unplanned hospital admissions each year. Nearly a third of these admitted patients are re-admitted to hospital within 28 days of discharge. Whilst there is a move within the NHS to ensure that people with long-term conditions receive more co-ordinated care, there is little research evidence to support an optimum approach to this in COPD. This study aims to evaluate the effectiveness of introducing standardised packages of care i.e. care bundles, for patients with acute exacerbations of COPD as a means of improving hospital care and reducing re-admissions. METHODS / DESIGN: This mixed-methods evaluation will use a controlled before-and-after design to examine the effect of, and costs associated with, implementing care bundles for patients admitted to hospital with an acute exacerbation of COPD, compared with usual care. It will quantitatively measure a range of patient and organisational outcomes for two groups of hospitals - those who deliver care using COPD care bundles, and those who deliver care without the use of COPD care bundles. These care bundles may be provided for patients with COPD following admission, prior to discharge or at both points in the care pathway. The primary outcome will be re-admission to hospital within 28 days of discharge, although the study will additionally investigate a number of secondary outcomes including length of stay, total bed days, in-hospital mortality, costs of care and patient / carer experience. A series of nested qualitative case studies will explore in detail the context and process of care as well as the impact of COPD bundles on staff, patients and carers. DISCUSSION: The results of the study will provide information about the effectiveness of care bundles as a way of managing in-hospital care for patients with an acute exacerbation of COPD. Given the number of unplanned hospital admissions for this patient group and their rate of subsequent re-admission, it is hoped that this evaluation will make a timely contribution to the evidence on care provision, to the benefit of patients, clinicians, managers and policy-makers. TRIAL REGISTRATION: International Standard Randomised Controlled Trials – ISRCTN13022442 - 11 February 201

    Chronicles of Oklahoma

    No full text
    Article describes the difficulties farmers faced during the Dust Bowl era in their daily lives through the personal narrative of Caroline A. Henderson. Virginia C. Purdy edited the piece and provides an introduction for historical context

    New method to measure interbreath intervals in infants for the assessment of apnoea and respiration

    No full text
    Background Respiratory disorders, including apnoea, are common in preterm infants due to their immature respiratory control compared with term-born infants. However, our inability to accurately measure respiratory rate in hospitalised infants results in unreported episodes of apnoea and an incomplete picture of respiratory activity. Methods We develop, validate and use a novel algorithm to identify interbreath intervals (IBIs) and apnoeas in preterm infants. In 42 preterm infants (1600 hours of recordings), we assess IBIs from the chest electrical impedance pneumograph using an adaptive amplitude threshold for the detection of breaths. The algorithm is refined by comparing its accuracy with clinically observed breaths and pauses in breathing. We develop an automated classifier to differentiate periods of true apnoea from artefactually low amplitude signal. We assess the performance of this algorithm in the detection of morphine-induced respiratory depression. Finally, we use the algorithm to investigate whether retinopathy of prematurity (ROP) screening alters the IBI distribution. Results Individual breaths were detected with a false-positive rate of 13% and a false-negative rate of 12%. The classifier identified true apnoeas with an accuracy of 93%. As expected, morphine caused a significant shift in the IBI distribution towards longer IBIs. Following ROP screening, there was a significant increase in pauses in breathing that lasted more than 10 s (t-statistic=1.82, p=0.023). This was not reflected by changes in the monitor-derived respiratory rate and no episodes of apnoea were recorded in the medical records. Conclusions We show that our algorithm offers an improved method for the identification of IBIs and apnoeas in preterm infants. Following ROP screening, increased respiratory instability can occur even in the absence of clinically significant apnoeas. Accurate assessment of infant respiratory activity is essential to inform clinical practice

    Aided cortical auditory evoked potentials in infants with frequency-specific synthetic speech stimuli: sensitivity, repeatability, and feasibility

    No full text
    Objectives: the cortical auditory evoked potential (CAEP) test is a candidate for supplementing clinical practice for infant hearing aid users and others who are not developmentally ready for behavioral testing. Sensitivity of the test for given sensation levels (SLs) has been reported to some degree, but further data are needed from large numbers of infants within the target age range, including repeat data where CAEPs were not detected initially. This study aims to assess sensitivity, repeatability, acceptability, and feasibility of CAEPs as a clinical measure of aided audibility in infants.Design: one hundred and three infant hearing aid users were recruited from 53 pediatric audiology centers across the UK. Infants underwent aided CAEP testing at age 3 to 7 months to a mid-frequency (MF) and (mid-)high-frequency (HF) synthetic speech stimulus. CAEP testing was repeated within 7 days. When developmentally ready (aged 7-21 months), the infants underwent aided behavioral hearing testing using the same stimuli, to estimate the decibel (dB) SL (i.e., level above threshold) of those stimuli when presented at the CAEP test sessions. Percentage of CAEP detections for different dB SLs are reported using an objective detection method (Hotellings T2). Acceptability was assessed using caregiver interviews and a questionnaire, and feasibility by recording test duration and completion rate.Results: the overall sensitivity for a single CAEP test when the stimuli were ≥0 dB SL (i.e., audible) was 70% for the MF stimulus and 54% for the HF stimulus. After repeat testing, this increased to 84% and 72%, respectively. For SL >10 dB, the respective MF and HF test sensitivities were 80% and 60% for a single test, increasing to 94% and 79% for the two tests combined. Clinical feasibility was demonstrated by an excellent >99% completion rate, and acceptable median test duration of 24 minutes, including preparation time. Caregivers reported overall positive experiences of the test.Conclusions: by addressing the clinical need to provide data in the target age group at different SLs, we have demonstrated that aided CAEP testing can supplement existing clinical practice when infants with hearing loss are not developmentally ready for traditional behavioral assessment. Repeat testing is valuable to increase test sensitivity. For clinical application, it is important to be aware of CAEP response variability in this age group
    corecore